| Name: |
Shimadzu GC-2010 Single Split/Splitless Injector |
| Item: |
#10335 |
| Pirce: |
|
| |
 |
System Includes:
- Single Split/Splitless Injector
- Single Flame Ionization Detector (FID)
- Fast Oven Cooling Option
- Automatic Pressure Control (APC)
- 110V/60Hz
- User Manual
- ONE (1) YEAR WARRANTY
Specifications
| Column Oven |
| Temperature Range |
(Ambient + 4°C) ~ 450°C (using LCO2 gas: -50°C - 450°C) |
| Inner Dimensions and Volume |
280 (W) x 280 (H) x 175 (D) mm, 13.7L |
| Temperature accuracy |
±1% of the set temperature in Kelvin unit (calibration at 0.01°C increments) |
| Temperature Variation Coefficient |
0.01°C/°C |
| Temperature Program Steps |
Up to 20 (cooling program possible) |
| Programmed rate setting range |
-250°C ~ 250°C/min |
| Total time for all steps |
9999.99 minutes max. |
| Injection Ports |
| Temperature Range |
Up to 400°C |
| Heating Settings |
1°C steps |
| No. of units installed simultaneously |
Up to 3 units |
| Sample injection unit types |
Split/splitless injection is standard
Direct (without split) injection unit (option)
On-column/PTV (programmable temperature vaporizer)injection unit (option) |
| Flow Control Unit |
| Advanced Flow Controller (AFC) |
| Split/splitles injection mode and direct injection mode |
Pressure range: 0-970kPa |
| Programmable Steps |
7 (Negative pressure step is available) |
| Programmed Rate Setting Range |
-400 ~ 400kPa/min |
| Split Ratio Range |
0 - 9999.9 |
| Mass Flow Rate Setting Range |
0 - 1200mL/min |
| Constant Linear Velocity |
Maintains optimum separation at all times |
| Available Optional Accessories |
| AOC-20i Auto Injector |
Direct injection, PTV/LVI, 1 - 250 uL syringes, ambient headspace |
| AOC-20s Auto Sampler |
150 1.5mL vials or 96 4mL vials and barcode reader |
| Leap Combi-Pal Autosampler |
SPME, headspace and micro-titer plate sampling capability |
| PY2020D Pyrolyzer |
Single or double shot includes autosampler |
| ? |
? |
| Detectors |
| Four detectors can be installed simultaneously and individually temperature controlled. Detector gas is electronically controlled by APC (Advanced Pressure Control) |
| Detector Type(s) |
FID, TCD, ECD, FPD, FTD |
| Flame Ionization Detector (FID) |
| Temperature Range |
450°C max. |
| Minimum detected quantity |
3pgC/s (Dodecane) |
| Dynamic Range |
107 |
| Thermal Conductivity Detector (TCD) |
| Temperature Range |
400°C max. |
| Dynamic Range |
105 |
| Sensitivity |
20,000 mV - mL/mg (Decane) |
| Electron Capture Detector (ECD) |
| Temperature Range |
350°C max. |
| Minimum detected quantity |
8fg/s |
| Dynamic Range |
104 |
| Flame Photometric Detector (FPD) |
| Temperature Range |
350°C max. |
| Dynamic Range |
P: 104
S: 103 |
| Minimum detected quantity |
P: 0.2pgP/s (tributyl phosphate)
S: 4pgS/s (dodecane thiol) |
Flame Thermionic Detector (FTD)
(Two types, one for capillary and one for packed. The specifications are the same.) |
| Temperature Range |
450°C max. |
| Dynamic Range |
N: 104
P: 104 |
| Minimum detected quantity |
N: 0.2pgN/s (azobenzene)
P: 0.03pgP/s (malathion) |
| Maximum of 2 detectors to keep instrument performance |
| Dimensions, Weight, Power Requirements (GC main unit) |
| Dimensions |
515 (W) x 440 (H) x 530 (D) mm |
| Weight |
30 kg (FID model) |
| Power Requirements |
AC100V/120V 230V
1800VA (Normal oven type) or
2600VA (High power oven type), 50/60Hz |
|
 |
|
Back
|
|
|
|